Reference: PV thermography of a commercial roof in Celje
Thermographic inspection of a 100 kWp rooftop system on a commercial building in Celje, flown in line with IEC TS 62446-3. Result: one failed string and 19 modules needing action, each with its position.
- Object
- Rooftop system on a commercial building in Celje, Slovenia, 100 kWp, 426 modules
- Method
- Aerial thermography in line with IEC TS 62446-3, irradiance 731 W/m², about 12 mm per pixel
- Equipment
- DJI Matrice 4TD with radiometric thermal camera and RTK, evaluation with dronalise
- Result
- Failed string with 17 modules, 19 modules rated defect, finding per module with coordinate
View project →